Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.594
Filtrar
1.
Wei Sheng Yan Jiu ; 53(2): 294-299, 2024 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-38604967

RESUMO

OBJECTIVE: To establish an analytical method for determining the migration of 24 elements in Yixing clay pottery in 4% acetic acid simulated solution by inductively coupled plasma mass spectrometry. METHODS: Four types of Yixing clay pottery, including Yixing clay teapot, Yixing clay kettle, Yixing clay pot, and Yixing clay electric stew pot, were immersed in 4% acetic acid as a food simulant for testing. The migration amount of 24 elements in the migration solution was determined using inductively coupled plasma mass spectrometry. RESULTS: Lithium, magnesium, aluminum, iron, and barium elements with a mass concentration of 1000 µg/L; Lead, cadmium, total arsenic, chromium, nickel, copper, vanadium, manganese, antimony, tin, zinc, cobalt, molybdenum, silver, beryllium, thallium, titanium, and strontium elements within 100 µg/L there was a linear relationship within, the r value was between 0.998 739 and 0.999 989. Total mercury at 5.0 µg/L, there was a linear relationship within, the r value of 0.995 056. The detection limit of the elements measured by this method was between 0.5 and 45.0 µg/L, the recovery rate was 80.6%-108.9%, and the relative standard deviation was 1.0%-4.8%(n=6). A total of 32 samples of four types of Yixing clay pottery sold on the market, including teapots, boiling kettles, casseroles, and electric stewing pots, were tested. It was found that the migration of 16 elements, including beryllium, titanium, chromium, nickel, cobalt, zinc, silver, cadmium, antimony, total mercury, thallium, tin, copper, total arsenic, molybdenum, and lead, were lower than the quantitative limit. The element with the highest migration volume teapot was aluminum, magnesium, and barium; The kettle was aluminum and magnesium; Casserole was aluminum, magnesium, and lithium; The electric stew pot was aluminum. CONCLUSION: This method is easy to operate and has high accuracy, providing an effective and feasible detection method for the determination and evaluation of element migration in Yixing clay pottery.


Assuntos
Arsênio , Mercúrio , Oligoelementos , Cobre , Molibdênio/análise , Níquel , Argila , Magnésio , Alumínio/análise , Cádmio/análise , Bário/análise , Titânio/análise , Prata/análise , Berílio/análise , Estanho/análise , Arsênio/análise , Lítio/análise , Antimônio/análise , Tálio/análise , Zinco , Cromo , Cobalto/análise , Mercúrio/análise , Espectrometria de Massas , Acetatos , Oligoelementos/análise
2.
J Vis Exp ; (205)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38557764

RESUMO

This protocol describes the synthesis of Au nanoparticle seeds and the subsequent formation of Au-Sn bimetallic nanoparticles. These nanoparticles have potential applications in catalysis, optoelectronics, imaging, and drug delivery. Previously, methods for producing alloy nanoparticles have been time-consuming, require complex reaction conditions, and can have inconsistent results. The outlined protocol first describes the synthesis of approximately 13 nm Au nanoparticle seeds using the Turkevich method. The protocol next describes the reduction of Sn and its incorporation into the Au seeds to generate Au-Sn alloy nanoparticles. The optical and structural characterization of these nanoparticles is described. Optically, prominent localized surface plasmon resonances (LSPRs) are apparent using UV-visible spectroscopy. Structurally, powder X-ray diffraction (XRD) reflects all particles to be less than 20 nm and shows patterns for Au, Sn, and multiple Au-Sn intermetallic phases. Spherical morphology and size distribution are obtained from transmission electron microscopy (TEM) imaging. TEM reveals that after Sn incorporation, the nanoparticles grow to approximately 15 nm in diameter.


Assuntos
Ligas de Ouro , Nanopartículas Metálicas , Prata/química , Ouro/química , Estanho , Nanopartículas Metálicas/química , Ligas/química
3.
Food Chem ; 447: 139036, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38518615

RESUMO

In this study, a UV-Vis Spectroscopy-based method was developed for the determination of tin(IV) in epilobium parviflorum tea samples after preconcentration. The preconcentration process was carried out using the liquid-liquid microextraction technique. Before starting the analysis, optimization studies were carried out for the variables likely to affect the experimental results. As a result of the analyzes performed under optimum conditions, the detection limit of our method was calculated as 16.83 µg/L. The percent relative standard deviation value was calculated as 1.25% (n = 8) and linearity was found in the range of 10-1000 µg/L. Recovery experiments were performed on epilobium parviflorum tea samples using the matrix matching method. As a result of the analyzes made on teas belonging to three different brands, recovery results ranging from 92 to 117% were obtained.


Assuntos
Epilobium , Microextração em Fase Líquida , Solventes , Solventes Eutéticos Profundos , Estanho , Microextração em Fase Líquida/métodos , Análise Espectral , Chá , Limite de Detecção
4.
Sci Rep ; 14(1): 6519, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38499602

RESUMO

In this study, tin dioxide nanoparticles (SnO2 NPs) were successfully synthesized through an eco-friendly method using basil leaves extract. The fabricated SnO2 NPs demonstrated significant adsorption capabilities for phenol (PHE), p-nitrophenol (P-NP), and p-methoxyphenol (P-MP) from water matrices. Optimal conditions for maximum removal efficiency was determined for each phenolic compound, with PHE showing a remarkable 95% removal at a 3 ppm, 0.20 g of SnO2 NPs, pH 8, and 30 min of agitation at 35 °C. Molecular docking studies unveiled a potential anticancer mechanism, indicating the ability of SnO2 NPs to interact with the epidermal growth factor receptor tyrosine kinase domain and inhibit its activity. The adsorption processes followed pseudo-second order kinetics and Temkin isotherm model, revealing spontaneous, exothermic, and chemisorption-controlled mechanisms. This eco-friendly approach utilizing plant extracts was considered as a valuable tool for nano-sorbent production. The SnO2 NPs not only exhibit promise in water treatment and also demonstrate potential applications in cancer therapy. Characterization techniques including scanning electron microscopy, UV-visible spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction spectroscopy (XRD), and energy-dispersive X-ray spectroscopy (EDAX) provided comprehensive insights into the results.


Assuntos
Nanopartículas , Estanho , Simulação de Acoplamento Molecular , Óxidos , Nanopartículas/química , Fenol , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X , Extratos Vegetais/química
5.
BMC Med Imaging ; 24(1): 49, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395772

RESUMO

PURPOSE: Unenhanced abdominal CT constitutes the diagnostic standard of care in suspected urolithiasis. Aiming to identify potential for radiation dose reduction in this frequent imaging task, this experimental study compares the effect of spectral shaping and tube voltage modulation on image quality. METHODS: Using a third-generation dual-source CT, eight cadaveric specimens were scanned with varying tube voltage settings with and without tin filter application (Sn 150, Sn 100, 120, 100, and 80 kVp) at three dose levels (3 mGy: standard; 1 mGy: low; 0.5 mGy: ultralow). Image quality was assessed quantitatively by calculation of signal-to-noise ratios (SNR) for various tissues (spleen, kidney, trabecular bone, fat) and subjectively by three independent radiologists based on a seven-point rating scale (7 = excellent; 1 = very poor). RESULTS: Irrespective of dose level, Sn 100 kVp resulted in the highest SNR of all tube voltage settings. In direct comparison to Sn 150 kVp, superior SNR was ascertained for spleen (p ≤ 0.004) and kidney tissue (p ≤ 0.009). In ultralow-dose scans, subjective image quality of Sn 100 kVp (median score 3; interquartile range 3-3) was higher compared with conventional imaging at 120 kVp (2; 2-2), 100 kVp (1; 1-2), and 80 kVp (1; 1-1) (all p < 0.001). Indicated by an intraclass correlation coefficient of 0.945 (95% confidence interval: 0.927-0.960), interrater reliability was excellent. CONCLUSIONS: In abdominal CT with maximised dose reduction, tin prefiltration at 100 kVp allows for superior image quality over Sn 150 kVp and conventional imaging without spectral shaping.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem
6.
J Dent ; 143: 104895, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38387598

RESUMO

OBJECTIVES: To compare the remineralisation efficacy and ion bioavailability of two novel SnF2-containing dentifrices in a blinded, cross-over, randomised in situ clinical study. METHODS: Six participants wore removal palatal appliances holding human enamel and dentine blocks with subsurface lesions. Appliances were worn for two treatment periods of 14 consecutive days each, with a one-week washout period in-between. Participants were randomly allocated to rinse with a 1:5 diluted coded slurry of one of two dentifrices containing either 5 % casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) +1100 ppm F as SnF2 [MIPOP], or 1100 ppm F as SnF2 [CT], for 1 min, four times a day. Saliva was collected post-treatment and analysed for tin, calcium, inorganic phosphate and fluoride ions using atomic absorption spectrophotometry and ion chromatography. Enamel and dentine lesions were analysed for percent remineralisation (%R) using transverse microradiography and percent surface microhardness recovery (%SMHR). RESULTS: MIPOP released significantly higher F (3.00 ± 0.27 mM), Ca (15.23 ± 3.23 mM) and Sn (1.18 ± 0.13 mM) into saliva whereas CT released 2.89 ± 0.32 mM F and only 0.84 ± 0.11 mM Ca and 0.28 ± 0.10 mM Sn. MIPOP produced significantly higher %R than CT: 25.6 ± 1.5 % compared to 15.2 ± 0.7 % in enamel, and 33.6 ± 3.1 % compared to 20.6 ± 1.1 % in dentine. Additionally, MIPOP produced significantly higher %SMHR (18.2 ± 7.9 %) compared to CT (4.1 ± 0.6 %). CONCLUSIONS: Both dentifrices promoted remineralisation, but the MIPOP dentifrice with added CPP-ACP and the ion-stabilising effects of CPP released higher amounts of bioavailable tin and produced significantly higher remineralisation and surface microhardness recovery. CLINICAL SIGNIFICANCE: Modern dentifrices contain SnF2 for a range of oral health benefits. Challenges associated with stability of these formulations can affect ion bioavailability, reducing efficacy. Two dentifrices with SnF2 promoted remineralisation in situ, however the dentifrice with the added saliva biomimetic CPP-ACP was superior and therefore may produce greater health benefits.


Assuntos
Dentifrícios , Fluoretos de Estanho , Humanos , Fluoretos de Estanho/farmacologia , Fluoretos de Estanho/uso terapêutico , Dentifrícios/uso terapêutico , Fluoreto de Sódio/uso terapêutico , Estanho/farmacologia , Remineralização Dentária/métodos , Fluoretos/farmacologia , Esmalte Dentário/patologia , Estudos Cross-Over , Dentina , Cariostáticos/farmacologia
7.
J Dent ; 143: 104901, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38417610

RESUMO

OBJECTIVES: To assess the effect of different tin-containing toothpastes on the control of erosive tooth wear in enamel and dentin. METHODS: Enamel and dentin slabs were randomly distributed into 7 experimental groups (n = 10/substrate): C-: negative control (Artificial saliva); AmF (regular fluoridated toothpaste without tin); Sn-1 (SnF2/NaF); Sn-2 (SnF2/NaF/SnCl2); Sn-3 (SnCl2/NaF); Sn-4 (SnF2/SnCl2); Sn-5 (SnCl2/AmF/NaF/chitosan). Specimens were submitted to 5-day erosion-abrasion cycling. Surface loss (SL) was determined with an optical profilometer. Tin deposition on the tooth surfaces and some characteristics of the toothpastes (pH, potentially available F-, %weight of solid particles, and RDA) were also assessed. Data were statistically analyzed (α = 0.05). RESULTS: For enamel, the Sn-2 presented the lowest SL, not differing significantly from AmF, C+, and Sn-3. The SL of these groups was significantly lower than the C-, except for Sn-3. Sn-1 and Sn-4 were also not significantly different from C-. For dentin, C- significantly showed the highest SL values, whilst, Sn-1 presented the lowest SL, not differing significantly from AmF, Sn-2, C+, and Sn-3. There was a significant positive association between enamel SL and the pH and tin deposition. Dentin SL was significantly negatively associated with the %weight of solid particles and RDA. CONCLUSIONS: Most of the tin-toothpastes were able to exhibit some protection against ETW. In this process, the toothpastes characteristics play a role, as lower enamel SL was significantly associated with lower pH values and tin deposition; and lower dentin SL was associated with higher %weight of solid particles and RDA of the toothpastes. CLINICAL SIGNIFICANCE: Tin-containing toothpastes can be used for erosive tooth wear protection, but our study showed that their effect depends on the pH, amount of tin deposition, % weight of solid particles and RDA of the toohpastes.


Assuntos
Compostos de Estanho , Abrasão Dentária , Erosão Dentária , Desgaste dos Dentes , Humanos , Fluoretos de Estanho/farmacologia , Cremes Dentais/farmacologia , Fluoretos/farmacologia , Erosão Dentária/prevenção & controle , Estanho , Abrasão Dentária/prevenção & controle , Fluoreto de Sódio/farmacologia , Escovação Dentária
8.
Anal Chim Acta ; 1294: 342294, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38336410

RESUMO

BACKGROUND: Tin and lead contamination is a global threat to marine ecosystems considering their species-specific toxicity, bioavailability and mobility. Hence simultaneous measurement of multiple tin and lead compounds at µg L-1 to pg L-1 levels in environmental water is always an indispensable but challengeable task. High performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) is one of the most widely used choices for this purpose because of good sensitivity, strong separation power and good compatibility. Previous HPLC-ICP-MS methods based on a single elemental speciation strategy are low-efficiency and sensitivity-insufficient for a large set of unstable samples and interaction of multiple metal(loid)s down to ng L-1 levels. RESULTS: In this study, we developed a sensitive, efficient and environment-friendly analytical method for accurate quantification of inorganic and organic species of tin and lead simultaneously based on HPLC-ICP-MS with online integration of solid phase extraction (SPE). By using graphene oxide modified silica conditioned with 1 mM benzoic acid to enrich tin and lead species from 10 mL sample, detection limits were improved to 2-8 pg per liter due to satisfactory enrichment factors (522-2848 folds). The SPE-HPLC-ICP-MS method was applicable to quantification of ultra-trace tin and lead species at pg L-1 levels in uncontaminated seawater. Tributyltin was the only tin species detected at subnanograms per liter levels while Pb(II) was the only lead species detected at several nanograms per liter in thirteen coastal seawater samples collected in Hangzhou Bay, indicating light contamination of tin and lead. SIGNIFICANCE: Overall, the proposed SPE-HPLC-ICP-MS method is highly sensitive, efficient and environment-friendly that are fairly suitable to routine speciation analysis of tin and lead in environmental, food, and biological samples.


Assuntos
Chumbo , Estanho , Espectrometria de Massas/métodos , Cromatografia Líquida de Alta Pressão/métodos , Ecossistema , Água do Mar , Extração em Fase Sólida/métodos
9.
J Dairy Sci ; 107(3): 1311-1333, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38423728

RESUMO

Whole milk powder (WMP) manufactured in New Zealand in 1907 was sent to the Antarctic continent with the Shackleton-led British Antarctic Expedition from 1907 to 1909. This powder was stored at ambient conditions at Shackleton's Hut at Cape Royds, Antarctica, for over 100 yr before a sample was collected on behalf of Fonterra by the Antarctic Heritage Trust. Having spent most of its existence both dried and in frozen storage, any deleterious reactions within the WMP would have been markedly retarded. The composition and some properties of the roller-dried Shackleton's WMP are reported along with those of 2 modern spray-dried New Zealand WMP. The Shackleton powder was less white and more yellow than the modern WMP and was composed of flakes rather than agglomerated particles, consistent with that expected of a roller-dried powder. Headspace analysis showed lipolytic and oxidative volatile compounds were present in the Shackleton WMP, indicting some deterioration of the milk either before powder manufacture or on storage of the finished product. On a moisture-free basis, the Shackleton WMP had higher protein, higher fat (with a markedly higher free fat level), higher ash, and a lower lactose level than the modern WMP. The lysine level was lower in the Shackleton WMP compared with the spray-dried powders, whereas the fatty acid composition was relatively similar. The sodium level was markedly higher in the Shackleton WMP compared with the spray-dried powder, which is probably due to the addition of an alkaline sodium salt to adjust the pH of the milk before roller drying. Lead, iron, and tin levels were markedly higher in the Shackleton WMP compared with the spray-dried powders, possibly due to the equipment used in powder manufacture and the tin-plated cases used for storage. The proteins in the Shackleton WMP were more lactosylated than in the spray-dried powders. The Shackleton WMP had a higher ratio of κ-casein A to B variants and a higher ratio of ß-lactoglobulin B to A variants than the spray-dried powders, whereas the αS1-casein, ß-casein, αS2-casein, and α-lactalbumin protein variants were similar in all powders. The total phospholipid content was markedly lower in the Shackleton WMP than the spray-dried powders, primarily due to a lower phosphatidylethanolamine concentration. The molecular species distributions within the phospholipid classes were generally similar in the 3 powders. Claims are sometimes encountered that the milk of today is different from that consumed by previous generations. However, this comparative study has shown that the Shackleton WMP was generally similar to modern WMP. Although differences in some components and properties were observed, these were attributable to the manufacturing equipment and processes used in the pioneering years of WMP manufacture.


Assuntos
Gelo , Leite , Animais , Leite/química , Pós/química , Gelo/análise , Estanho/análise , Caseínas/análise , Fosfolipídeos/análise , Sódio/análise
10.
J Clin Hypertens (Greenwich) ; 26(2): 187-196, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38214193

RESUMO

There are limited data available regarding the connection between hypertension and heavy metal exposure. The authors intend to establish an interpretable machine learning (ML) model with high efficiency and robustness that identifies hypertension based on heavy metal exposure. Our datasets were obtained from the US National Health and Nutrition Examination Survey (NHANES, 2013-2020.3). The authors developed 5 ML models for hypertension identification by heavy metal exposure, and tested them by 10 discrimination characteristics. Further, the authors chose the optimally performing model after parameter adjustment by Genetic Algorithm (GA) for identification. Finally, in order to visualize the model's ability to make decisions, the authors used SHapley Additive exPlanation (SHAP) and Local Interpretable Model-Agnostic Explanations (LIME) algorithm to illustrate the features. The study included 19 368 participants in total. A best-performing eXtreme Gradient Boosting (XGB) with GA for hypertension identification by 16 heavy metals was selected (AUC: 0.774; 95% CI: 0.772-0.776; accuracy: 87.7%). According to SHAP values, Barium (0.02), Cadmium (0.017), Lead (0.017), Antimony (0.008), Tin (0.007), Manganese (0.006), Thallium (0.004), Tungsten (0.004) in urine, and Lead (0.048), Mercury (0.035), Selenium (0.05), Manganese (0.007) in blood positively influenced the model, while Cadmium (-0.001) in urine negatively influenced the model. Study participants' hypertension associated with heavy metal exposure was identified by an efficient, robust, and interpretable GA-XGB model with SHAP and LIME. Barium, Cadmium, Lead, Antimony, Tin, Manganese, Thallium, Tungsten in urine, and Lead, Mercury, Selenium, Manganese in blood are positively correlated with hypertension, while Cadmium in blood is negatively correlated with hypertension.


Assuntos
Compostos de Cálcio , Hipertensão , Mercúrio , Metais Pesados , Óxidos , Selênio , Humanos , Cádmio/urina , Inquéritos Nutricionais , Antimônio/urina , Manganês , Tálio/urina , Tungstênio/urina , Bário/urina , Estanho , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Metais Pesados/efeitos adversos , Metais Pesados/urina , Aprendizado de Máquina
11.
Eur Spine J ; 33(2): 706-712, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38233628

RESUMO

PURPOSE: Since childhood exposure to radiation has been demonstrated to increase cancer risk with increase in radiation dose, reduced radiation exposure during computed tomography (CT) evaluation is desired for adolescent idiopathic scoliosis (AIS). Therefore, this retrospective study aimed to investigate the radiation dose of dual-source CT using a spectral shaping technique and the accuracy of the thoracic pedicle screw (TPS) placement for posterior spinal fusion (PSF) in patients with AIS. METHODS: Fifty-nine female patients with thoracic AIS who underwent PSF using CT-guided TPSs were included and divided into two groups comprised of 23 patients who underwent dual-source CT (DSCT) with a tin filter (DSCT group) and 36 who underwent conventional multislice CT (MSCT group). We assessed the CT radiation dose using the CT dose index (CTDIvol), effective dose (ED), and accuracy of TPS insertion according to the established Neo's classification. RESULTS: The DSCT and MSCT groups differed significantly (p < 0.001) in the mean CTDIvol (0.76 vs. 3.31 mGy, respectively) and ED (0.77 vs. 3.47 mSv, respectively). Although the correction rate of the main thoracic curve in the DSCT group was lower (65.7% vs. 71.2%) (p = 0.0126), the TPS accuracy (Grades 0-1) was similar in both groups (381 screws [88.8%] vs. 600 screws [88.4%], respectively) (p = 0.8133). No patient required replacement of malpositioned screws. CONCLUSION: Spectral shaping DSCT with a tube-based tin filter allowed a 75% radiation dose reduction while achieving TPS insertion accuracy similar to procedures based on conventional CT without spectral shaping.


Assuntos
Escoliose , Humanos , Adolescente , Feminino , Criança , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Estanho , Tomografia Computadorizada por Raios X , Ácido Dioctil Sulfossuccínico , Fenolftaleína
12.
Food Chem ; 443: 138552, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38295562

RESUMO

Tin and lead are a global concern considering their species-dependent toxicity, bioavailability and transformation. Simultaneous speciation analysis of tin and lead is challenging for a large food capacity containing unstable species. Herein, we developed two sensitive methods for rapid quantification of tin and lead species in Antarctic seafood by high-performance liquid chromatography and inductively coupled plasma mass spectrometry based on strong cation-exchange and Amphion columns. Inorganic tin and lead, four organotin and two organolead compounds can be analysed in 16 min on a 10-cm Amphion II column (mobile phase: 4 mM sodium dodecyl benzene sulfonate at pH 2.0) with 0.02-0.24 µg L-1 detection limits. The method was applied to Antarctic krill and fish, demonstrating the presence of any tin and lead species down to µg kg-1 level. Overall, the proposed methods are sensitive, efficient and environment-friendly for routine speciation analysis of tin and lead in food samples.


Assuntos
Euphausiacea , Estanho , Animais , Espectrometria de Massas/métodos , Cromatografia Líquida de Alta Pressão/métodos , Chumbo , Alimentos Marinhos , Peixes , Cátions
13.
Caries Res ; 58(2): 81-89, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198764

RESUMO

INTRODUCTION: Erosive tooth wear is a highly prevalent dental condition that is modified by the ever-present salivary pellicle. The aim of the present in situ study was to investigate the effect of polyphenols on the ultrastructure of the pellicle formed on dentin in situ and a subsequent erosive challenge. METHODS: The pellicle was formed on bovine dentin specimens for 3 min or 2 h in 3 subjects. After subjects rinsed with sterile water (negative control), 1% tannic acid, 1% hop extract, or tin/fluoride solution containing 800 ppm tin and 500 ppm fluoride (positive control), specimens were removed from the oral cavity. The erosive challenge was performed on half of the specimens with 1% citric acid, and all specimens were analyzed by transmission electron microscopy. Incorporation of tannic acid in the pellicle was investigated by fluorescence spectroscopy. RESULTS: Compared to the negative control, ultrastructural analyses reveal a thicker and electron-denser pellicle after application of polyphenols, in which, according to spectroscopy, tannic acid is also incorporated. Application of citric acid resulted in demineralization of dentin, but to a lesser degree when the pellicle was pretreated with a tin/fluoride solution. The pellicle was more acid-resistant than the negative control when modified with polyphenols or tin/fluoride solution. CONCLUSION: Polyphenols can have a substantial impact on the ultrastructure and acid resistance of the dentin pellicle, while the tin/fluoride solution showed explicit protection against erosive demineralization.


Assuntos
Esmalte Dentário , Erosão Dentária , Humanos , Animais , Bovinos , Película Dentária , Fluoretos/farmacologia , Erosão Dentária/prevenção & controle , Estanho/farmacologia , Polifenóis/farmacologia , Fluoretos de Estanho/farmacologia , Ácido Cítrico/efeitos adversos , Dentina
14.
São Paulo; s.n; 20240103. 69 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1524322

RESUMO

Este estudo teve o objetivo de desenvolver um gel experimental contendo flúor e estanho, como uma opção de tratamento profissional, para ser utilizado na prevenção da erosão dental. Foram utilizados 50 fragmentos (4mm × 4mm × 2mm) de esmalte e 50 de dentina, obtidos de incisivos bovinos. Os fragmentos foram incluídos em resina acrílica, planificados e polidos. Em seguida, uma fita adesiva foi posicionada sobre a superfície polida desses espécimes, deixando uma janela de 4mm × 1mm exposta aos testes subsequentes. Os espécimes foram previamente erodidos (10min em solução de ácido cítrico a 1%, pH~2,4) e distribuídos aleatoriamente em cinco grupos experimentais (n=10 para cada substrato), de acordo com os seguintes tratamentos: 1. F+Sn+HPMC: Gel de fluoreto de sódio e cloreto de estanho experimental (7500 ppm F- e 15000 ppm Sn2+, pH=4,5); 2. F+HPMC: Gel de fluoreto de sódio experimental (7500 ppm F-, pH=4,5); 3. Comercial: Gel de flúor fosfato acidulado comercial - APF (12300 ppm F-, pH=3,2); 4. Placebo: Gel placebo (Hidroxipropil MetilceluloseHPMC, sem componentes ativos); 5. Controle negativo: sem tratamento; aplicados por 60 s. Na sequência, os espécimes foram submetidos a uma ciclagem de erosão-re-deposição mineral, que consistia em 5 min de imersão em solução de ácido cítrico a 0,3% (pH~2,6), seguido de imersão em saliva artificial por 60min, 4x/dia, durante 5 dias. A perda de superfície dos espécimes (PS em m) foi determinada com um perfilômetro óptico após 5, 10 e 20 dias de ciclagem. Os dados obtidos foram analisados com ANOVA de dois fatores de medidas repetidas, considerando um nível de significância de 5%. Para o esmalte, o placebo não diferiu do controle em nenhum tempo experimental, e ambos apresentaram significativamente a maior PS. Após 5 e 10 dias: (F+Sn+HPMC)=(comercial)<(F+HPMC)<(placebo)=(controle). Após 20 dias: (F+Sn+HPMC)=(F+HPMC)=(comercial)<(controle)=(placebo). Para dentina, no 5º dia: (comercial)=(F+Sn+HPMC)=(F+HPMC)<(controle)=(placebo). No 10º dia, os grupos F+Sn+HMC, comercial e F+HPMC continuaram apresentando menor PS do que o controle e o placebo, porém, F+HPMC não diferiu significativamente desses dois últimos grupos. No 20º dia, somente o comercial apresentou menor PS que controle e placebo. Considerando as limitações desse estudo in vitro, pode-se concluir que o gel de F+Sn+HPMC foi capaz de controlar a progressão da erosão dental de maneira semelhante ao gel comercial, que possui 4800 ppm a mais de fluoreto em sua composição, exceto após 20 dias de desafio erosivo na dentina. Esse gel é uma alternativa clínica viável, podendo ser potencialmente utilizado em conjunto com produtos de uso diário, visando o aumento da proteção contra erosão em indivíduos com alto risco para erosão dental.


Assuntos
Estanho , Fluoretos de Estanho , Erosão Dentária
15.
PLoS One ; 19(1): e0296084, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38165873

RESUMO

This study aims to provide a concise overview of the behavior exhibited by Sn-doped ZnO crystals using a computational technique known as density functional theory (DFT). The influence of Sn doping on the electronic, structural, and optical properties of ZnO have been explored. Specifically, the wavelength dependent refractive index, extinction coefficient, reflectance, and absorption coefficient, along with electronic band gap structure of the Sn doped ZnO has been examined and analyzed. In addition, X-ray diffraction (XRD) patterns have been obtained to investigate the structural characteristics of Sn-doped ZnO crystals with varying concentrations of Sn dopant atoms. The incorporation of tin (Sn) into zinc oxide (ZnO) has been observed to significantly impact the opto-electronic properties of the material. This effect can be attributed to the improved electronic band structure and optical characteristics resulting from the tin doping. Furthermore, the controllable structural and optical characteristics of tin-doped zinc oxide will facilitate the development of various light-sensitive devices. Moreover, the impact of Sn doping on the optoelectronic properties of ZnO is thoroughly investigated and documented.


Assuntos
Óxido de Zinco , Óxido de Zinco/química , Estanho/química , Difração de Raios X , Compostos de Estanho/química
16.
Molecules ; 29(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38257375

RESUMO

This study investigates the impacts of bismuth and tin on the production of CH4 and volatile fatty acids in a microbial electrosynthesis cell with a continuous CO2 supply. First, the impact of several transition metal ions (Ni2+, Fe2+, Cu2+, Sn2+, Mn2+, MoO42-, and Bi3+) on hydrogenotrophic and acetoclastic methanogenic microbial activity was evaluated in a series of batch bottle tests incubated with anaerobic sludge and a pre-defined concentration of dissolved transition metals. While Cu is considered a promising catalyst for the electrocatalytic conversion of CO2 to short chain fatty acids such as acetate, its presence as a Cu2+ ion was demonstrated to significantly inhibit the microbial production of CH4 and acetate. At the same time, CH4 production increased in the presence of Bi3+ (0.1 g L-1) and remained unchanged at the same concentration of Sn2+. Since Sn is of interest due to its catalytic properties in the electrochemical CO2 conversion, Bi and Sn were added to the cathode compartment of a laboratory-scale microbial electrosynthesis cell (MESC) to achieve an initial concentration of 0.1 g L-1. While an initial increase in CH4 (and acetate for Sn2+) production was observed after the first injection of the metal ions, after the second injection, CH4 production declined. Acetate accumulation was indicative of the reduced activity of acetoclastic methanogens, likely due to the high partial pressure of H2. The modification of a carbon-felt electrode by the electrodeposition of Sn metal on its surface prior to cathode inoculation with anaerobic sludge showed a doubling of CH4 production in the MESC and a lower concentration of acetate, while the electrodeposition of Bi resulted in a decreased CH4 production.


Assuntos
Bismuto , Euryarchaeota , Dióxido de Carbono , Metano , Estanho , Esgotos , Acetatos , Íons
17.
Med Phys ; 51(1): 103-112, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37962008

RESUMO

BACKGROUND: Studies of tin spectral filtration have demonstrated potential in reducing radiation dose while maintaining image quality for unenhanced computed tomography (CT) scans. The extent of dose reduction, however, was commonly measured using the change in the scanner's reported CTDIvol . This method does not account for how tin filtration affects patient organ and effective dose. PURPOSE: To investigate the effect of tin filtration on patient organ and effective dose for CT Lung Cancer Screening (LCS) and CT Colonography (CTC). METHODS: A previously-developed Monte Carlo program was adapted to model a 96-row CT scanner (Somatom Force, Siemens Healthineers) with tin filtration capabilities at 100 kV (100Sn) and 150 kV (150Sn). The program was then validated using experimental CTDIvol measurements at all available kV (70-150 kV) and tin-filtered kV options (100Sn and 150Sn). After validation, the program simulated LCS scans of the chest and CTC scan of the abdomen-pelvis for a population of 53 computational patient models from the extended cardiac-torso family. Each scan was performed using three different spectra: 120 kV, 100Sn, and 150Sn. CTDIvol -normalized organ doses and DLP-normalized effective doses, commonly referred to as dose conversion factors, were compared between the different spectra. RESULTS: For all LCS and CTC scans, CTDIvol -normalized organ doses and DLP-normalized effective doses increased with increasing beam hardness (120 kV, 100Sn, 150 Sn). For LCS, relative for 120 kV, conversion factors for 100Sn produced a median increase in effective dose of 9%, with organ dose increases of 8% to lung, 5% to breast, 15% to thyroid, and 3% to skin. Conversion factors for 150Sn produced a median increase in effective dose of 20%, with organ dose increases of 16%, 18%, 26%, and 12% to these same organs, respectively. For CTC, relative for 120 kV, conversion factors for 100Sn produced a median increase in effective dose of 12%, with organ dose increases of 9% to colon, 10% to liver, 11% to stomach, and 4% to skin. Conversion factors for 150Sn produced a median increase in effective dose of 21%, with organ dose increases of 16%, 17%, 19%, and 10% to these same organs, respectively. CONCLUSIONS: Results show that dose conversion factors are greater when using tin filtration and should be considered when evaluating tin's potential for dose reduction.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Pulmonares , Humanos , Estanho , Doses de Radiação , Detecção Precoce de Câncer , Neoplasias Pulmonares/diagnóstico por imagem
18.
Eur J Radiol ; 170: 111209, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37992609

RESUMO

PURPOSE: To investigate the metal artifact suppression potential of combining tin prefiltration and virtual monoenergetic imaging (VMI) for osseous microarchitecture depiction in ultra-high-resolution (UHR) photon-counting CT (PCCT) of the lower extremity. METHOD: Derived from tin-filtered UHR scans at 140 kVp, polychromatic datasets (T3D) and VMI reconstructions at 70, 110, 150, and 190 keV were compared in 117 patients with lower extremity metal implants (53 female; 62.1 ± 18.0 years). Three implant groups were investigated (total arthroplasty [n = 48], osteosynthetic material [n = 43], and external fixation [n = 26]). Image quality was assessed with regions of interest placed in the most pronounced artifacts and adjacent soft tissue, measuring the respective attenuation. Additionally, artifact extent, bone-metal interface interpretability and overall image quality were independently evaluated by three radiologists. RESULTS: Artifact reduction was superior with increasing keV level of VMI. While T3D was superior to VMI70keV (p ≥ 0.117), artifacts were more severe in T3D than in VMI ≥ 110 keV (all p ≤ 0.036). Image noise was highest for VMI70keV (all p < 0.001) and lowest for VMI110keV with comparable results for VMI110keV - VMI190keV. Subjective image quality regarding artifacts was superior for VMI ≥ 110 keV (all p ≤ 0.042) and comparable for VMI110keV - VMI190keV. Bone-metal interface interpretability was superior for VMI110keV (all p ≤ 0.001), while T3D, VMI150keV and VMI190keV were comparable. Overall image quality was deemed best for VMI110keV and VMI150keV. Interreader reliability was good in all cases (ICC ≥ 0.833). CONCLUSIONS: Tin-filtered UHR-PCCT scans of the lower extremity combined with VMI reconstructions allow for efficient artifact reduction in the vicinity of bone-metal interfaces.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Feminino , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Próteses e Implantes , Processamento de Imagem Assistida por Computador/métodos , Metais , Artefatos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído , Estudos Retrospectivos
19.
AJR Am J Roentgenol ; 222(1): e2329950, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37646386

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT could be useful to help address the typically high radiation doses of conventional energy-integrating detector (EID) CT of the lumbar spine. OBJECTIVE. The purpose of our study was to compare PCD CT and EID CT of the lumbar spine, both performed using tin filtration, in terms of radiation dose and image quality. METHODS. This study included a prospective sample of 39 patients (22 men, 17 women; mean age, 27.2 years) who underwent investigational PCD CT of the lumbar spine as part of a separate study and a retrospective sample of 39 patients (22 men, 17 women; mean age, 34.9 years) who underwent clinically indicated EID CT of the lumbar spine. In both groups, all examinations were performed using unenhanced technique with tin prefiltration between June 2022 and January 2023. Patients were matched between groups using age, sex, and BMI. A custom gaussian curve-fitting algorithm was used to automatically calculate image noise, SNR, and CNR for each examination, on the basis of all voxels within the image set. Three radiologists independently reviewed examinations to perform a subjective visual assessment of visualization of trabecular architecture, cortical bone, neuroforaminal content, paraspinal muscles, and intervertebral disk, as well as overall image quality, using a 4-point Likert scale (1 = poor, 4 = excellent). PCD CT and EID CT examinations were compared. RESULTS. Mean CTDIvol was 4.4 ± 1.0 (SD) mGy for PCD CT versus 11.1 ± 1.9 mGy for EID CT (p < .001). Mean size-specific dose estimate (SSDE) was 6.2 ± 1.0 (SD) mGy for PCD CT versus 14.2 ± 1.8 mGy for EID CT (p < .001). PCD CT and EID CT examinations were not significantly different in terms of image noise or SNR (both p > .05). PCD CT, in comparison with EID CT, showed significantly higher CNR (mean ± SD, 33.6 ± 3.3 vs 29.3 ± 4.1; p < .001). For all three readers, the median score for overall image quality was 4 (range, 3-4) for both PCD CT and EID CT. PCD CT and EID CT examinations showed no significant difference in terms of any qualitative measure for any reader (all p > .05). CONCLUSION. PCD CT, in comparison with EID CT, yielded significantly lower radiation dose with preserved image quality. CLINICAL IMPACT. The findings support expanded use of PCD CT for lumbar spine evaluation.


Assuntos
Fótons , Estanho , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Estudos Retrospectivos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
20.
AJR Am J Roentgenol ; 222(1): e2329765, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37646387

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT may allow lower radiation doses than used for conventional energy-integrating detector (EID) CT, with preserved image quality. OBJECTIVE. The purpose of this study was to compare PCD CT and EID CT, reconstructed with and without a denoising tool, in terms of image quality of the osseous pelvis in a phantom, with attention to low radiation doses. METHODS. A pelvic phantom comprising human bones in acrylic material mimicking soft tissue underwent PCD CT and EID CT at various tube potentials and radiation doses ranging from 0.05 to 5.00 mGy. Additional denoised reconstructions were generated using a commercial tool. Noise was measured in the acrylic material. Two readers performed independent qualitative assessments that entailed determining the denoised EID CT reconstruction with the lowest acceptable dose and then comparing this reference reconstruction with PCD CT reconstructions without and with denoising, using subjective Likert scales. RESULTS. Noise was lower for PCD CT than for EID CT. For instance, at 0.05 mGy and 100 kV with tin filter, noise was 38.4 HU for PCD CT versus 48.8 HU for EID CT. Denoising further reduced noise; for example, for PCD CT at 100 kV with tin filter at 0.25 mGy, noise was 19.9 HU without denoising versus 9.7 HU with denoising. For both readers, lowest acceptable dose for EID CT was 0.10 mGy (total score, 11 of 15 for both readers). Both readers somewhat agreed that PCD CT without denoising at 0.10 mGy (reflecting reference reconstruction dose) was relatively better than the reference reconstruction in terms of osseous structures, artifacts, and image quality. Both readers also somewhat agreed that denoised PCD CT reconstructions at 0.10 mGy and 0.05 mGy (reflecting matched and lower doses, respectively, with respect to reference reconstruction dose) were relatively better than the reference reconstruction for the image quality measures. CONCLUSION. PCD CT showed better-quality images than EID CT when performed at the lowest acceptable radiation dose for EID CT. PCD CT with denoising yielded better-quality images at a dose lower than lowest acceptable dose for EID CT. CLINICAL IMPACT. PCD CT with denoising could facilitate lower radiation doses for pelvic imaging.


Assuntos
Fótons , Estanho , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação , Pelve
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...